Oriental Instruments & Dongyi Technology

Oriental Instruments & Dongyi Technology

Targeting global production of helium leak detection equipment; independently developed quality flow meter filling machines, with customers spread across various domestic refrigeration enterprises, enjoying high recognition in the industry.

Oriental Instruments & Dongyi Technology

Oriental Instruments & Dongyi Technology

Refrigerant charging machines are used in industries such as air conditioning, refrigerators (cabinets), water dispensers, and automotive air conditioning; the specially developed power supply is applied to vacuum equipment and charging equipment, such as coating machines, high vacuum exhaust equipment, and electric vehicle charging stations.

About Us

Specialized in the production of global helium leak detection equipment; independent development of mass flow meter metering method filling machine, customers all over the domestic refrigeration enterprises

Develop new products with high and new technology, so that products develop in depth and breadth to meet market demand

----

Chengdu Oriental Instruments Co., Ltd. is located at No. 199, Section 2, Chongsuan Avenue, Economic Development Zone, Chongzhou City, Chengdu. The company enjoys a beautiful environment and convenient transportation. It was established in Chengdu in 1993 under the name “Chengdu Dongfang Instruments Factory,” and its predecessor was the state-owned Chengdu Semiconductor Materials Factory. The company began manufacturing roll-to-roll vacuum coating equipment in 2013 and now possesses 13 years of experience in the technology, design, and manufacturing of such equipment. The company’s main products include: automatic nitrogen leak detectors, nitrogen filling and recovery systems, vacuum roll-to-roll coating equipment and dedicated power supplies, vacuum drying and degreasing systems, refrigerant charging systems, vacuum purification and oil injection systems, and nitrogen mass spectrometer leak detectors. These products are widely used in industries such as refrigeration, automotive, packaging, power, energy, capacitors and batteries, foundry, nuclear, and defense.

View Details
1993 Year

The company was founded in 1993

1237.6 + million

Registered capital: 12.376 million yuan

20000 Piece

Monthly production capacity of 20000 pieces

150 +

More than 150 employees

Products

Our company's current main products include refrigerant charging machines, explosion-proof charging machines, winding vacuum coating equipment, vacuum purification oil-injection machines, specialized power supplies, and nitrogen testing equipment. Refrigerant charging machines are used in industries such as air conditioning, refrigerators, water dispensers, and automotive air conditioning.

Specialized in the production of global helium leak detection equipment

Self-developed mass flow meter metering method filling machine

Sales Hotline:

8613908209306(Equipment)

8613908085776(Power supply and module)

Oriental Instruments-Patent Certificate

Our company is also specialized in the face of military, nuclear energy and other special units have special needs of helium inspection equipment. Our company's helium leak detection equipment has also obtained the national invention certificate (certificate number: ZL 201510341572.0)

条件:
清空条件

Utility Model Patent Certificate
< 1...5678 > proceed page

Oriental Instruments · News

The company's products have excellent performance and are well received by users. Its products have been distributed all over the country in the production enterprises of air conditioners, refrigerators, freezers, commercial air conditioners, central air conditioners and automobile air conditioners.

Company News

Company News

The main products of our company now include refrigerant filling machine, explosion-proof filling machine, vacuum purification filling machine, special power supply, helium inspection equipment, etc.

Industry dynamics

Industry Information

The company's products have excellent performance and are well received by users, and their products have been spread all over the country.

03

/

18

News dynamics

Factors Affecting Comfort in Summer - Refrigerant Charging Machine

In summer, the use of air conditioning cooling is essential, so a good refrigerant charging machine is a key factor in determining summer comfort. Before adding refrigerant to the car air conditioning, first evacuate for 1 hour. When the system has no leaks and is under vacuum, open the R134a bottle with the nozzle facing down, loosen the soft hose connector in the middle of the pressure gauge to release the air in the hose, and open the high-pressure side manual valve to inject liquid refrigerant from the high-pressure side.

08

/

17

News dynamics

How to correctly detect insufficient refrigerant

The weighing and charging method is the truly correct method, applicable to any refrigeration system. The method involves weighing the amount of refrigerant to be charged, and what needs to be done is to find out the amount or range of refrigerant to be charged from the relevant data. This is not just an observation method, but a real charging method. As long as the manufacturer specifies the correct charging amount on the nameplate for water-cooled cabinets or split units, weighing and charging can be done using a beam scale, electronic scale, dial scale, or other weighing devices after completely drying and evacuating the system. This charging method is the most suitable. For a system with some refrigerant, there are two methods to charge the refrigerant. 1. Release the already charged Freon, re-evacuate, and weigh for charging; Many maintenance personnel are reluctant to spend time recovering the refrigerant from a system that is undercharged before recharging. In this case, the following alternative method can be used. However, this is a comprehensive application of all the methods mentioned earlier or one or two of them. Note: Before using these methods, ensure that all coils are clean and that the airflow is correct. 2. Use the following method to continue adding refrigerant, measuring and recording all data. A. Charge while simultaneously checking superheat and subcooling. For air-cooled direct expansion systems, set the subcooling to 8~12°C and superheat to 7~8°C. B. Check the temperature difference between the inlet and outlet air of the coil. Ensure that the airflow of the condenser and evaporator is correct, as well as under moderate load conditions. C. Check and compare the suction/discharge pressures. Look for standard data provided by the manufacturer in the installation, operation, and maintenance manual. D. If there is a sight glass, check for bubbles in the sight glass. If there are bubbles, confirm whether they are due to excessive pressure loss or insufficient refrigerant. E. Check the compressor current. If the current is too low, analyze the reasons for the low current under several types of operating conditions of the system.

08

/

13

News dynamics

Naming methods for refrigerants

Inorganic Compounds - The abbreviation for inorganic compounds is R7(). The parentheses represent a set of numbers, which is the integer part of the molecular weight of the inorganic substance.

Partner

Specialized in the production of global helium leak detection equipment; independent development of mass flow meter metering method filling machine, customers all over the domestic refrigeration enterprises, in the industry has a high reputation

Lichung Group

Lichung Group

Xingyu Co., Ltd.

Xingyu Co., Ltd.

New Fly

New Fly

Wanfeng

Wanfeng

Wanbao Refrigerator

Wanbao Refrigerator

SK

SK

Shengshida

Shengshida

Samsung

Samsung

Now flying

Now flying

Hualing Electric

Hualing Electric

View More

Online message

The main products of our company now include refrigerant filling machine, explosion-proof filling machine, vacuum purification filling machine, special power supply, helium inspection equipment, etc.

Submit Message

* Note: Please be sure to fill in the information accurately and keep the communication unblocked. We will get in touch with you as soon as possible.